Air speed, airflow and pressure
Choose the right metric and retain the fixture, distance, position and calculation.
Open method →Method library · sample acceptance
Use the same model, mode, distance, fixture, instrument and environmental conditions when comparing samples. Record the method before recording the result.
A test result is comparable only when its conditions are comparable. RPM, air speed, airflow, pressure, noise and runtime answer different questions and must not be substituted for one another.
Detailed methods
Each method defines the minimum record, common errors and evidence boundary.
Choose the right metric and retain the fixture, distance, position and calculation.
Open method →Control distance, room, background level, mode and instrument settings.
Open method →Bind time claims to the battery, mode, cutoff rule, adapter and thermal record.
Open method →Record the model and version, serial or sample ID, firmware, battery and charger, mode, fixture, instrument, calibration status, date, ambient temperature, operator and acceptance rule. Photograph the setup so a second reviewer can reproduce it.
An outlet air-speed value does not automatically equal total airflow and does not prove performance at a longer working distance.
Airflow requires a defined cross-section, fixture and calculation method. Static pressure requires an appropriate pressure setup and operating point. For engineering decisions, request the full method or fan curve rather than combining unrelated headline values.
| Record | Why |
|---|---|
| Measurement distance and orientation | Sound level changes materially with distance and direction. |
| Background noise | A quiet room and a noisy room cannot be compared directly. |
| Operating mode | Low, medium, high and turbo can produce different tonal characteristics. |
| Room and surface | Reflections can change the measured result. |
| Meter and weighting | The instrument setting is part of the result. |
Condition the sample as agreed, start from a declared state of charge and run the selected mode until the defined cutoff. Record accessory use, ambient conditions, voltage behavior and thermal observations. For charging, record the adapter, cable, input profile, time to the declared endpoint and any temperature limit.
The output should include the signed requirement, setup photos, raw readings, calculations, exceptions, pass/fail decision and reviewer. If the configuration changes after approval, classify the change and decide which checks must be repeated.
Agree on methods and acceptance limits before ordering a customized sample.